Erratas

모든 모델과 액세서리에 대한 모든 오류 사항을 정리한 표는 Complete Zivid Errata 확인할 수 있습니다.

Erratas per camera

Zivid 3

Key

Summary:

Revisions:

E-39

Zivid 2, Zivid 2+ and Zivid 3 cameras stop responding on the network after receiving an Ethernet frame larger than 1526 bytes

—

Workaround: Set the MTU to 1500 on every network interface on the same subnet as the camera, including the PC that runs the SDK. On Linux, for example: sudo ip link set dev <interface> mtu 1500.

  • M70 Rev B3

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

E-38

Capture hangs or fails on Intel GPUs when the application’s OpenCL queue waits on an incomplete user event

—

Workaround: Upgrade to Intel Compute Runtime 26.40.40196.8 or later, where the issue is fixed.

If upgrading is not possible, complete every user event that the application’s queue waits on before passing the queue to an SDK function or starting a capture.

  • M70 Rev B3

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

E-35

깜빡이는 주변광이 있는 환경에서 샘플링 간격을 사용할 때 색상 이미지에 간헐적인 불일치(임의의 색조 변화)가 발생합니다.

—

해결 방법: 깜빡임 현상을 완화하려면 샘플링 간격에 의존하기보다는 노출 시간을 조정하는 것이 좋습니다. 샘플링 간격을 사용해야 하는 경우, 영향을 받은 색상 이미지를 감지하고 수정하는 재촬영 루틴을 구현하십시오.

  • XL250 Rev A0

E-16

동일한 하드웨어일 경우 Windows에서 캡처하는 데 걸리는 시간은 Linux보다 더 길 수 있습니다.

—

해결 방법: GPU 코어와 메모리 클럭 속도를 잠그면 캡처 시간의 변동성을 줄일 수 있습니다(Nvidia GPU만 해당).

  • M70 Rev B3

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

E-15

Windows에서 캡처 시간은 가끔 더 길어질 수 있습니다(정상보다 1초 이상 더 길어질 수 있음)

—

해결 방법: Windows의 네트워크 드라이버 설정에서 “Receive Buffers” 와 “ransmit Buffers” 를 늘려 패킷 손실 발생을 줄이세요.

  • M70 Rev B3

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

Fixed issues

Key

Summary:

Revisions:

Fixed in:

E-37

프로젝터 열 안정화 기능으로 인해 밝기를 0으로 설정한 2D 캡처 이미지에서 밝기 변화가 발생할 수 있습니다.

  • M70 Rev B3

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

v2.18.0

E-36

일부 Zivid 3 XL250 카메라에서 2D 샘플링 간격 설정을 사용할 때 캡처된 RGB 이미지의 색조가 이상하게 나타납니다.

  • XL250 Rev A0

v2.17.2

E-34

이더넷 연결이 느린 경우 전체 해상도 HDR로 캡처할 때 카메라가 재부팅됩니다.

  • M130 Rev A0

  • MR130 Rev A0

  • XL250 Rev A0

v2.17.1

Zivid 2+

Key

Summary:

Revisions:

E-39

Zivid 2, Zivid 2+ and Zivid 3 cameras stop responding on the network after receiving an Ethernet frame larger than 1526 bytes

—

Workaround: Set the MTU to 1500 on every network interface on the same subnet as the camera, including the PC that runs the SDK. On Linux, for example: sudo ip link set dev <interface> mtu 1500.

  • Rev A0

E-38

Capture hangs or fails on Intel GPUs when the application’s OpenCL queue waits on an incomplete user event

—

Workaround: Upgrade to Intel Compute Runtime 26.40.40196.8 or later, where the issue is fixed.

If upgrading is not possible, complete every user event that the application’s queue waits on before passing the queue to an SDK function or starting a capture.

  • Rev A0

E-16

동일한 하드웨어일 경우 Windows에서 캡처하는 데 걸리는 시간은 Linux보다 더 길 수 있습니다.

—

해결 방법: GPU 코어와 메모리 클럭 속도를 잠그면 캡처 시간의 변동성을 줄일 수 있습니다(Nvidia GPU만 해당).

  • Rev A0

E-15

Windows에서 캡처 시간은 가끔 더 길어질 수 있습니다(정상보다 1초 이상 더 길어질 수 있음)

—

해결 방법: Windows의 네트워크 드라이버 설정에서 “Receive Buffers” 와 “ransmit Buffers” 를 늘려 패킷 손실 발생을 줄이세요.

  • Rev A0

Fixed issues

Key

Summary:

Revisions:

Fixed in:

E-37

프로젝터 열 안정화 기능으로 인해 밝기를 0으로 설정한 2D 캡처 이미지에서 밝기 변화가 발생할 수 있습니다.

  • Rev A0

v2.18.0

E-34

이더넷 연결이 느린 경우 전체 해상도 HDR로 캡처할 때 카메라가 재부팅됩니다.

  • Rev A0

v2.17.1

E-33

GenICam/HALCON 포인트 클라우드는 Zivid Studio보다 더 어둡게 나타납니다.

  • Rev A0

v2.14.0

E-32

Halcon에서 낮은 해상도 포인트 클라우드가 실패한 후 더 높은 해상도 포인트 클라우드 캡처(GenICam만 해당)

  • Rev A0

v2.14.0

E-30

내보낸 PLY/PCD/XYZ 포인트 클라우드는 Zivid Studio보다 더 어둡게 나타납니다.

  • Rev A0

v2.14.0

E-29

Zivid 2/2+는 Zivid::Experimental::Projection::showImage()를 사용할 때 잘못된 이미지를 표시할 수 있습니다.

  • Rev A0

v2.11.1

E-28

PC 프로세스가 캡처 중에 중단되면 Zivid 2/2+가 응답하지 않거나 오프라인으로 표시될 수 있습니다.

  • Rev A0

v2.12.0

E-23

Zivid 2의 펌웨어 업데이트는 드물게 시간 초과로 실패할 수 있습니다.

  • Rev A0

v2.14.0

E-14

캡처 중 “CameraImageTimeout” 또는 “Timeout” 예외가 발생했습니다.

  • Rev A0

v2.14.0

E-10

PC 프로세스가 캡처 중에 중단되면 Zivid 2/2+가 작동을 멈추고 15초 후에 재부팅될 수 있습니다.

  • Rev A0

v2.13.0

Zivid 2

Key

Summary:

Revisions:

E-39

Zivid 2, Zivid 2+ and Zivid 3 cameras stop responding on the network after receiving an Ethernet frame larger than 1526 bytes

—

Workaround: Set the MTU to 1500 on every network interface on the same subnet as the camera, including the PC that runs the SDK. On Linux, for example: sudo ip link set dev <interface> mtu 1500.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • L110 Rev A0

  • M130 Rev A0

  • M60 Rev A0

  • LR110 Rev A0

  • MR130 Rev A0

  • MR60 Rev A0

  • XL250 Rev A0

E-38

Capture hangs or fails on Intel GPUs when the application’s OpenCL queue waits on an incomplete user event

—

Workaround: Upgrade to Intel Compute Runtime 26.40.40196.8 or later, where the issue is fixed.

If upgrading is not possible, complete every user event that the application’s queue waits on before passing the queue to an SDK function or starting a capture.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • L110 Rev A0

  • M130 Rev A0

  • M60 Rev A0

  • LR110 Rev A0

  • MR130 Rev A0

  • MR60 Rev A0

  • XL250 Rev A0

E-24

Zivid 2 공장 초기화 버튼이 작동하지 않을 수 있습니다.

—

해결 방법: https://support.zivid.com/en/latest/support/reset-button-failure.html

  • Rev A0

  • Rev B2

  • Rev B3

E-16

동일한 하드웨어일 경우 Windows에서 캡처하는 데 걸리는 시간은 Linux보다 더 길 수 있습니다.

—

해결 방법: GPU 코어와 메모리 클럭 속도를 잠그면 캡처 시간의 변동성을 줄일 수 있습니다(Nvidia GPU만 해당).

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • L110 Rev A0

  • M130 Rev A0

  • M60 Rev A0

  • LR110 Rev A0

  • MR130 Rev A0

  • MR60 Rev A0

  • XL250 Rev A0

E-15

Windows에서 캡처 시간은 가끔 더 길어질 수 있습니다(정상보다 1초 이상 더 길어질 수 있음)

—

해결 방법: Windows의 네트워크 드라이버 설정에서 “Receive Buffers” 와 “ransmit Buffers” 를 늘려 패킷 손실 발생을 줄이세요.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • L110 Rev A0

  • M130 Rev A0

  • M60 Rev A0

  • LR110 Rev A0

  • MR130 Rev A0

  • MR60 Rev A0

  • XL250 Rev A0

Fixed issues

Key

Summary:

Revisions:

Fixed in:

E-37

프로젝터 열 안정화 기능으로 인해 밝기를 0으로 설정한 2D 캡처 이미지에서 밝기 변화가 발생할 수 있습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • L110 Rev A0

  • M130 Rev A0

  • M60 Rev A0

  • LR110 Rev A0

  • MR130 Rev A0

  • MR60 Rev A0

  • XL250 Rev A0

v2.18.0

E-33

GenICam/HALCON 포인트 클라우드는 Zivid Studio보다 더 어둡게 나타납니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.14.0

E-32

Halcon에서 낮은 해상도 포인트 클라우드가 실패한 후 더 높은 해상도 포인트 클라우드 캡처(GenICam만 해당)

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.14.0

E-30

내보낸 PLY/PCD/XYZ 포인트 클라우드는 Zivid Studio보다 더 어둡게 나타납니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.14.0

E-29

Zivid 2/2+는 Zivid::Experimental::Projection::showImage()를 사용할 때 잘못된 이미지를 표시할 수 있습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.11.1

E-28

PC 프로세스가 캡처 중에 중단되면 Zivid 2/2+가 응답하지 않거나 오프라인으로 표시될 수 있습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.12.0

E-23

Zivid 2의 펌웨어 업데이트는 드물게 시간 초과로 실패할 수 있습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.14.0

E-17

Ubuntu 20.04 및 Intel GPU에서 “CL_OUT_OF_RESOURCES” 또는 “OpenGL error: GL_INVALID_OPERATION” 발생

  • Rev A0

  • Rev B2

  • Rev B3

v2.7.0

E-14

캡처 중 “CameraImageTimeout” 또는 “Timeout” 예외가 발생했습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.14.0

E-10

PC 프로세스가 캡처 중에 중단되면 Zivid 2/2+가 작동을 멈추고 15초 후에 재부팅될 수 있습니다.

  • L100 Rev A0

  • M70 Rev B2

  • M70 Rev B3

  • Rev A0

v2.13.0

E-9

Windows에서 OpenCV 어설션 오류

  • Rev A0

  • Rev B2

  • Rev B3

v2.4.1