Warmup
Zivid Studio can warm up the camera and track its progress in a side panel, so the camera reaches thermal equilibrium before you capture or calibrate. A Zivid camera heats up while it is used, and the small mechanical changes this causes reduce 3D accuracy until then.
This page describes the Studio interface. For more on why warmup matters and how long to warm up, see the warmup tutorial.
Prerequisites
Install Zivid Software.
A connected Zivid camera.
Optional, but recommended: a Zivid calibration board, to also track local trueness during warmup.
Opening the Warmup panel
Go to Tools → Warmup with a camera connected. The Warmup panel replaces the capture controls on the right. Select Tools → Exit Warmup to close it. Close the Hand-Eye Calibration window first, because the two cannot be open at the same time (see Using several tools in one session).
Running a warmup
Place the Zivid calibration board in the camera’s view (optional, but recommended; use Live Scene View to check the placement).
Set the Capture interval to match your application’s capture cycle.
Click Start Warmup.
Studio captures repeatedly using the current capture settings, and plots the lens temperature and the local trueness error over time. The warmup stops automatically once the lens temperature stops changing, which means the camera has reached thermal equilibrium. You can stop it early with Stop Warmup.
Capture interval
The Min and Max values set how often Studio captures while warming up, in seconds. Match them to the capture cadence of your application, because a camera warmed with a different cadence settles at a different temperature. A fast, continuous cycle warms the camera quickly, while a slow or intermittent cycle lets it cool between captures.
Warmup Plot
The plot shows the lens temperature on the left axis and the local trueness error on the right axis as the warmup progresses. A live readout below the plot shows the current lens temperature, its rate of change, the elapsed time, and the local trueness error. Use the detach button, or drag the plot’s header out of the window, to follow the plot in a separate window while you work.
Local trueness is measured only while the Zivid calibration board is in view. Without the board, the warmup still runs and stops the same way, but the plot shows only the temperature. Keeping the board in view is better, because the trueness curve shows when the 3D accuracy has settled.
Next steps
Infield Correction to verify and correct the camera’s dimension trueness once it is warm.
Warm-up for the concepts behind camera warmup.