A Zivid Studio session is the shared on-disk workspace for the Hand-Eye Calibration, Warmup, and Infield Correction tools, and the session manager creates and opens them.
Each tool reads and writes the current session, so the captures, calibration result, and verification data for one camera and robot setup stay together. Studio saves a session automatically, so there is no Save or Save As action.
Prerequisites
What a session contains
A session is a folder on disk, not a single file.
Studio creates each session in the session root folder and names it with a timestamp, for example 20261110_143005.
By default, the root folder is %LOCALAPPDATA%\Zivid\CalibrationSessions on Windows and ~/.local/share/Zivid/CalibrationSessions on Linux.
To use another folder, click Browse… next to Root folder in the session manager.
Studio remembers the root folder you last used.
A session.yml file inside the folder marks it as a session and holds its settings: the mounting (eye-in-hand or eye-to-hand), whether low-DOF is used, the calibration object, the marker configuration, and the default robot-pose rotation format.
Studio can also open a session saved by the Hand-Eye GUI with RoboDK, which has a session_info.json file instead, and takes the mounting, the calibration object, and the markers from it.
The captured data lives in subfolders of the session:
Warmup: the warmup captures.
Infield: the infield correction data.
Calibration: the hand-eye pose pairs and the resulting transform.
Calibration/Verification-Projection, Calibration/Verification-Stitching, and Calibration/Verification-Touch: the verification datasets.
Disk usage
Sessions take up disk space, because Studio saves the captured point clouds in them without asking. With experimental features enabled, Studio saves a full point cloud (ZDF file) for every hand-eye pose pair, every Infield Correction capture, and every stitching verification capture. Warmup saves only a small CSV file with the temperature and trueness readings.
Studio does not delete sessions that contain data (it removes only an empty session when it starts). To free disk space, delete the session folders you no longer need from the root folder shown in the session manager.
Opening the session manager
Go to Tools → Session → Sessions…, or click Sessions… in the Configuration panel of the Hand-Eye Calibration window. The Session submenu also shows the current session name, or No session open.
The dialog lists the sessions found in the root folder, newest first. Each row shows the session name, which tools already have data in it, and when it was last modified.
Creating and opening sessions
Click New Session to start an empty session in the current root folder.
Select a session and click Open, or double-click it, to switch to it.
Click Browse… next to Root folder to choose the folder that Studio scans for sessions.
Studio reopens your last session on startup. If that session is empty, Studio starts a fresh one instead.
Reviewing a saved session
Opening a session that already contains hand-eye pose pairs loads them for review: you cannot capture new pose pairs or delete existing ones. You can still change the configuration, recalibrate, and run verification captures. Studio saves these changes in the session, and backs up the original files the first time you change anything. To return to the session as it was collected, click Restore original (as collected) in the Configuration panel. To capture new pose pairs, click Start new session.
Using several tools in one session
Hand-Eye Calibration cannot be open at the same time as Infield Correction or Warmup, because they use the same camera and robot. If you open one while the other is open, Studio asks you to close the other first.
Infield Correction changes the camera’s correction, so a hand-eye calibration made before it no longer matches the camera. If the session already holds hand-eye pose pairs, opening Infield Correction offers to start a new session, so each hand-eye calibration stays with the correction it was made with. To use one session for all three tools, run Warmup and Infield Correction before you capture hand-eye pose pairs.
Next steps
Warmup to warm the camera, storing the captures in the session.
Infield Correction to verify and correct dimension trueness, storing the data in the session.
Hand-Eye Calibration to capture pose pairs and calibrate within a session.